Thursday, February 27, 2014

Pilot light problem on a carrier gas furnace

Pilot Light problem on a Carrier Gas furnace


[SIZE=3]I have a carrier Gas Furnace that has a problem with the pilot light. I will try to describe the problem. It has an automatic pilot igniter. Sometime the unit will start to light the pilot (High-voltage Clicking) and then stop. Try again and stop. Sometime it will light the pilot and after maybe 30s to 1min. it turns off. Now here is the strange part! If I push on the connector on the igniter board it will start back up. Let go of the connector and it turns off. Looked at the board were the connector is soldered to the board and it looked fine. I even re-soldered the connector. I even re-soldered some of the components around the connector. It did not help. At first the board was loose. The screws would not tighten up the board to the mount. I fixed that but it too did not help. After flexing the connector a few times the furnace started working correctly. Restarted the system several times with not problems. This has happen twice now. I though that maybe it was a grounding problem because the board was very loose on the mount. My question is this! Could it still be a grounding problem or should I just replace the Igniter/Lockout Controler?[/SIZE] Are you able to post a picture or at least the module model and make. If this is the one I think it is, that is a common problem. you will probably need to replace the module [SIZE=3]If you mean model and makeof the Igniter/Lockout Control box it is the LH33WZ512A. It is in a gray box and the Model and part number's are printed on a white label. It looks like the ones on Ebay if you do a search for that part number. I hope this is what you needed. Reggie[/SIZE] That module is known to fail. The fact that your furnace uses it means that your system is pretty old....... There are 2 modules out there to choose from. Are there any difference in these 2? 1 is the LW33WZ512A and the other is a ICM296. I'm guessing that the ICM296 is just a newer model. Which would be best? Reggie ICM module is aftermarket. I have had bad luck with ICM spark modules. A big thanks for your time and the information. That wasn't the module I was thinking of, however as hvactech states they also had problems. Appears you have had many years of service before it gave up.








Related Posts:




  • Pilot light will not stay lit when water is hot

    Pilot light will not stay lit when water is hotThe pilot light goes out when the burner has heated the water. In the morning, I can light the pilot by pushing the button down and striking the elec...


  • Pilot light goes out on gas fireplace after switch turned to on position

    Pilot light goes out on gas fireplace after switch turned to on positionI followed the instructions to light the pilot on my FP. (pushed pilot dial in, turned it to Pilot, pushed in ignitor button...


  • Pilot light wont light ao smith

    pilot light wont light AO SmithHello all, I have an AO Smith gas water heater and the pilot light wont light. GCV 50 200 Build date 10/ 27/ 2009 I followed directions, push gas control nob down in...


  • Pilot light on gas logs wont stay lit with logs on

    Pilot light on gas logs won't stay lit with logs onWe have just purchased vent free gas logs; with the logs off the pilot light will stay lit and the flame will work; with the logs on the pilot li...


  • Miller furnace problem

    Miller furnace problemI just bought a house with a 1996 Miller MMHA-070ABHR-05 furnace.The furnace starts,inducer fan runs and the burner comes on,but as soon as the blower kicks on it runs for 10...