Friday, February 28, 2014

Troybilt 5550 generator

Troybilt 5550 Generator


Model 01919-00 10 Hp Bs Ohv Engine. The Unit Is 3 Yrs Old Only Used A Few Hours Testing In The Spring. Tried To Use After Ts Fay And Unit Would Only Run For 15 Mins And Shut Off. Changed Gas Twice And New Plug Still Only Runs 10 To 15 Mins At A Time .you Can Pull Start As Soon As It Shuts Off. Used For 2 Days Until Power Restored. Unit Is Full Of Oil Does Anyone Have Any Reason For This Happening? Possible fuel cap venting problem, else I would suspect a problem in the carburetor. Hello Mark, Your Troybuilt model number doesn't tell me what model and type number Briggs engine you have on this unit. I will assume since it is a long run unit (large fuel tank) that it does have the low oil shut-down system (oil alert). About the time this unit was new (3 years ago) I had one come in with the same problem. After doing some testing the oil alert module under the top engine cover was at fault. Briggs had a small problem with this module being too sensitive once the oil heated and started splashing around in the crankcase, This caused a false low oil signal and would shut the engine down. They now have a replacement that will solve this problem. Your's can be tested by removing the plastic cover from the top of the engine; Disconnect the black wire at the module going to the coil back behind the shroud then test run the engine for a longer running time. If it then runs longer replace the oil alert module, If one is purchased you should receive the newer version. Good Luck Thanks For The Response I Had Tried Running With The Fuel Cap Loose But It Did Not Help. The Mod # 204412 0147e1 050118ye Bs I Pulled The Black Wire Off The Oil Sensor Because It Was Easier To Get To And The Unit Ran Solid For 3 Hours Before I Turned It Off. How Do You Tell If It Is The Oil Sensor Or The Oil Sensor Module? At Least The Unit Can Be Used Now If Heaven Forbid Another Storm Comes Our Way. Thanks Mark490 Mark, Here is the test procedure for the crankcase sensor. But, Keep in mind that it only acted up after running 10/15 minutes. So perform the test cold sitting then after warmed for 10/15 minutes. Good Luck








Related Posts:




  • Troy bilt 5550 generator 01919 not starting

    Troy Bilt 5550 Generator 01919 not startingI've got a Troy-Bilt generator model 01919 with a Briggs and Stratton engine model 204412. It was given to me a couple of years ago and has worked well a...


  • Troybilt tb475ss 4cycle problem

    Troybilt TB475SS 4-cycle problemHelp this thing is driving me nuts. I have become the neighborhood, will you fix it for me guy, anyway, the problem: the trimmer is very hard to start it will give...


  • Troybilt tb525cs 4cycle trimmer wont start

    Troy-Bilt TB525CS 4-Cycle Trimmer Won't StartHave had this for about four years, really haven't had any problems with it besides an oil leak from time to time over the years. Never found the sourc...


  • Rvonan generator repair

    RV-Onan Generator RepairOur Onan 5500 gas generator will not stay started. It will start as long as the start button is pushed down, as soon as you release the button the motor shuts off immediate...


  • Rv mounted onan generator

    RV mounted Onan GeneratorI have an Onan Marquis 7000 Generator in my 1994 34' Bounder Class A RV. It was running fine when I started it one afternoon and then shut it down. Then the next day it wo...