Reversing valve not switching

reversing valve not switching


This is a Goodman PHJ030-1A package heat pump. First: question is will low freon stop the reversing valve from switching? (Yes or No) Second: I check the reversing valve coil and found 24 volt going to it, it had 17.6 ohms. When call for heat the coil doesn't make any noise. How can I tell that the reversing valve is bad? Turn the unit over to AC or defrost. That should make the 4 way valve work. It runs as a AC when in defrost. But you say you have 24V at the coil. You can get a new coil and try it . Most units the 4 way only work for AC. Some older units the 4way would work on heat. That valve should work with a good charge of freon or no freon. Just what does the unit dont do?????????? Originally Posted by Ed Imeduc Turn the unit over to AC or defrost. That should make the 4 way valve work. It runs as a AC when in defrost. But you say you have 24V at the coil. You can get a new coil and try it . Most units the 4 way only work for AC. Some older units the 4way would work on heat. That valve should work with a good charge of freon or no freon. Just what does the unit dont do?????????? The compressor come on, cold air come out of the vents. When you set the thermostst to heat the unit stay in cool mode. I didn't check for amps on the coil. What amps should it be pulling? I have check coil to only to be bad. Sometime coil can check O.K., but bad. How can I really tell if the coil bad. Sometime coil can check O.K., but bad. How can I really tell if the coil bad. Can you hear it when you turn it on and off heat to cool. Do you feel the gas change in the lines when you go heat to cool? I don't hear the coil for the reversing valve making any sound when put in heat mode. Yes, in cool mode the coil that is mounted for the exchanger side get cold, cold air come from thvents. [Yes, in cool mode the coil that is mounted for the exchanger side get cold, cold air come from the vents Then it sounds like the valve is working. Most valves today dont have to work on heat . Just when you call for cool or defrost. Remember this is a Goodman. Goodman default is cool. I know you know this. The coil should energize in heat mode. That why I think the coil is bad. Cause when you call for heat you don't hear any noise from the coil. Find a simple SAFE way to connect and disconnect the power to the coil at the out door unit. Run the unit in which ever mode energizes the coil. With coil energized disconnect and connect power on and off. Does the valve shift? Discharge gas is what makes the valve shift. A low charge should still allow a shift. If you hear the coil click the valve may be stuck. If your EPA certified you could add Supco 8 oil to the system and exersize the valve and get it working. 9 times out of 10 Supco will save you from changing the valve. This is the reply that I was waiting for. Thanks








Related Posts:




  • Weilmclain indirect water heater safety valve

    Weil-McLain indirect water heater safety valveWe have a Weil-McLain indirect water heater which takes the hot water from our boiler at 180 degrees and circulates it around a tank with the domestic...


  • Sv9541 2094 smart valve issue

    SV9541 2094 Smart Valve issueHowdy All, Great forum! I have a natural gas furnace with the Honeywell SV9541 2094 Smart Valve and ST9160B 1050 Fan Control Board. We live in Wisconsin and it's summe...


  • Sticking eriehoneywell zone valve

    Sticking Erie/Honeywell zone valveI have a 16 year old Infloor radiant heating / DHW system that uses an Erie/Honeywell three way motorized 24 VAC valve to swap the boiler output between the radia...


  • Switching from electric to gas backup heat pump questions

    Switching From Electric to Gas Backup Heat Pump QuestionsHello all. I am in a house that is currently all electric (without an all electric discount). We've got two air exchange heat pumps that us...


  • Tac thermostat model 31100 for normallyopen zone valve

    TAC thermostat (model 31-100) for Normally-open zone valveMy condo has a central boiler on top of the 12-storey building that feeds hot water to baseboard heater in each unit. There is a room ther...